News
News
- What is a sacrificial anode
- Basic requirements for reference...
- What does the reference electrode do...
- Why are zinc blocks attached to the ...
- What is the principle of impressed...
- What material does metal structure...
Contact
Phone:18739187123
hotline:0391-7588881
E-mail:970512272@qq.com
Address:Wuzhi County, Jiaozuo City, China
Q & A
When the output voltage and current of potentiostat reach the maximum, C1 potential indicator drops?
- Author:Libo
- Source:wwww.catfishinglife.com
- Date:2021-06-11
- Click:0
Cause of failure: insulation flange short circuit; Or short circuit with other underground metal structures; Treatment method of reference electrode damage: repair short-circuit insulation flange, disconnect underground metal structure; Check the reference electrode measurement line or replace the reference electrode